AUDIXI 10 D: Screening, air and bone conduction, masking, automatic
audiometry (Hughson-Westlake), Speech audiometry (SRT, WRS, UCL/MCL) and over
threshold tests (SiSi & Weber; ABLB & Stenger; MLB & Decay; MCL
& UCL)
·
AUDIXI 10 D+: Screening, air and bone conduction, masking, automatic
audiometry (Hughson-Westlake), Speech audiometry (SRT, WRS, UCL/MCL) and over
threshold tests (SiSi & Weber; ABLB & Stenger; MLB & Decay; MCL
& UCL) including battery
·
AUDIXI 10 DHF: Screening, air and bone conduction, masking, automatic
audiometry (Hughson-Westlake), Speech audiometry (SRT, WRS, UCL/MCL) and over
threshold tests (SiSi & Weber; ABLB & Stenger; MLB & Decay; MCL
& UCL) with High Frequency
· AUDIXI 10 DHF+: Screening, air and bone conduction, masking, automatic audiometry (Hughson-Westlake), Speech audiometry (SRT, WRS, UCL/MCL) and over threshold tests (SiSi & Weber; ABLB & Stenger; MLB & Decay; MCL & UCL) with High Frequency and including battery
Clinic
Diagnosis smart-audiometer
· AUDIXI 10 D: Screening, air and bone conduction, masking, automatic audiometry (Hughson-Westlake), Speech audiometry (SRT, WRS, UCL/MCL) and over threshold tests (SiSi & Weber; ABLB & Stenger; MLB & Decay; MCL & UCL)
· AUDIXI 10 D+: Screening, air and bone conduction, masking, automatic audiometry (Hughson-Westlake), Speech audiometry (SRT, WRS, UCL/MCL) and over threshold tests (SiSi & Weber; ABLB & Stenger; MLB & Decay; MCL & UCL) including battery
· AUDIXI 10 DHF: Screening, air and bone conduction, masking, automatic audiometry (Hughson-Westlake), Speech audiometry (SRT, WRS, UCL/MCL) and over threshold tests (SiSi & Weber; ABLB & Stenger; MLB & Decay; MCL & UCL) with High Frequency
· AUDIXI 10 DHF+: Screening, air and bone conduction, masking, automatic audiometry (Hughson-Westlake), Speech audiometry (SRT, WRS, UCL/MCL) and over threshold tests (SiSi & Weber; ABLB & Stenger; MLB & Decay; MCL & UCL) with High Frequency and including battery
AUDIXI 10 D | AUDIXI 10 D+ | AUDIXI 10 DHF | AUDIXI 10 DHF+ |
REF: 10000207 | REF: 10000217 | REF: 10000208 | REF: 10000218 |
· CLINIC DIAGNOSTIC AUDIOMETER: · Screening · Via air conduction: - Level (max): -10 to 120dB HL - 11 Frequencies: 125 to 8000 Hz · Via bone conduction: - Level (max): -10 to 80db HL - 9 Frequencies: 250 to 6000 Hz · Masking: narrowband or wideband · Automatically tonal audiometry
(Hughson-Westlake) · Transducers Plug & Play system · Automated calibration system · Speech audiometry test: SRT, WRS, UCL, MCL
(sources: direct and/or recorded voice (CD, FLAC) · Over threshold tests: SiSi, Weber, ABLB, MLB, MCL, UCL, Decay and Stenger | · CLINIC DIAGNOSTIC AUDIOMETER WITH RECHARGEABLE BATTERY: · Screening · Via air conduction: - Level (max): -10 to 120dB HL - 11 Frequencies: 125 to 8000 Hz · Via bone conduction: - Level (max): -10 to 80db HL - 9 Frequencies: 250 to 6000 Hz · Masking: narrowband or wideband · Automatically tonal audiometry
(Hughson-Westlake) · Transducers Plug & Play system · Automated calibration system · Speech audiometry test: SRT, WRS, UCL, MCL
(sources: direct and/or recorded voice (CD, FLAC) · Over threshold tests: SiSi, Weber, ABLB, MLB,
MCL, UCL, Decay and Stenger · Li-Po 37Wh Battery | CLINIC DIAGNOSTIC AUDIOMETER WITH HIGH
FREQUENCY: · Screening · Via air conduction: - Level (max): -10 to 120dB HL - 11 Frequencies: 125 to 8000 Hz · Via bone conduction: - Level (max): -10 to 80db HL - 9 Frequencies: 250 to 6000 Hz · High Frequency tonal test: - Level (max): -10 to 100dB HL - 7 Frequencies: 8 to 16 kHz · Masking: narrowband or wideband · Automatically tonal audiometry
(Hughson-Westlake) · Transducers Plug & Play system · Automated calibration system · Speech audiometry test: SRT, WRS, UCL, MCL
(sources: direct and/or recorded voice (CD, FLAC) · Over threshold tests: SiSi, Weber, ABLB, MLB, MCL, UCL, Decay and Stenger | · CLINIC DIAGNOSTIC AUDIOMETER WITH HIGH
FREQUENCY AND RECHARGEABLE BATTERY: · Screening · Via air conduction: - Level (max): -10 to 120dB HL - 11 Frequencies: 125 to 8000 Hz · Via bone conduction: - Level (max): -10 to 80db HL - 9 Frequencies: 250 to 6000 Hz · High Frequency tonal test: - Level (max): -10 to 100dB HL - 7 Frequencies: 8 to 16 kHz · Masking: narrowband or wideband · Automatically tonal audiometry
(Hughson-Westlake) · Transducers Plug & Play system · Automated calibration system · Speech audiometry test: SRT, WRS, UCL, MCL
(sources: direct and/or recorded voice (CD, FLAC) · Over threshold tests: SiSi, Weber, ABLB, MLB,
MCL, UCL, Decay, Stenger · Li-Po 37Wh Battery |
HARDWARE Included:
·
Calibrated DD45 headphones (standard)
·
Calibrated B71W Bone Vibrator
·
Patient response switch
·
Power supply
·
Ethernet cable (network)
·
Patient microphone)
·
Operator headset
SOFTWARE Included:
· Data Base Software:
o Patients and tests database
o Patient management
o Appointment calendar management
· Diagnostic Suite:
o Test report with colour audiogram:
§
Index calculation: ELI, SAL and
Modified Klockhoff
§
Diagnostics including Hearing Loss
degree:
§
1979 AMA (American Medical
Association)
§
BSA: British Society of Audiology
§ Fletcher Index