AUDIXI 10 C: Screening, air and
bone conduction, masking, automatic audiometry (Hughson-Westlake) and Speech
audiometry (SRT, WRS, UCL/MCL)
·
AUDIXI 10 C+: Screening, air and
bone conduction, masking, automatic audiometry (Hughson-Westlake) and Speech
audiometry (SRT, WRS, UCL/MCL) including battery
·
AUDIXI 10 CHF: Screening, air and
bone conduction, masking, automatic audiometry (Hughson-Westlake) and Speech
audiometry (SRT, WRS, UCL/MCL) with High Frequency
· AUDIXI 10 CHF+: Screening, air and bone conduction, masking, automatic audiometry (Hughson-Westlake) and Speech audiometry (SRT, WRS, UCL/MCL) with High Frequency including battery
Advanced
Diagnosis smart-audiometer
AUDIXI 10 C | AUDIXI 10 C+ | AUDIXI 10 CHF | AUDIXI 10 CHF+ |
REF: 10000205 | REF: 10000215 | REF: 10000206 | REF: 10000216 |
ADVANCED DIAGNOSTIC AUDIOMETER: · Screening · Via air conduction: - Level (max): -10 to 120dB HL - 11 Frequencies: 125 to 8000 Hz · Via bone conduction: - Level (max): -10 to 80db HL - 9 Frequencies: 250 to 6000 Hz · Masking: narrowband or wideband · Automatically tonal audiometry
(Hughson-Westlake) · Transducers Plug & Play system · Automated calibration system · Speech audiometry test: SRT, WRS, UCL, MCL (sources: direct and/or recorded voice (CD, FLAC) | ADVANCED DIAGNOSTIC AUDIOMETER WITH
RECHARGEABLE BATTERY: · Screening · Via air conduction -10 to 120dB HL · 11 frequencies- Via air conduction: - Level (max): -10 to 120dB HL - 11 Frequencies: 125 to 8000 Hz · Via bone conduction: - Level (max): -10 to 80db HL - 9 Frequencies: 250 to 6000 Hz · Masking: narrowband or wideband · Automatically tonal audiometry
(Hughson-Westlake) · Transducers Plug & Play system · Automated calibration system · Speech audiometry test: SRT, WRS, UCL, MCL
(sources: direct and/or recorded voice (CD, FLAC) · Li-Po 37Wh Battery | ADVANCED DIAGNOSTIC AUDIOMETER WITH HIGH
FREQUENCY: · Screening · Via air conduction: - Level (max): -10 to 120dB HL - 11 Frequencies: 125 to 8000 Hz · Via bone conduction: - Level (max): -10 to 80db HL - 9 Frequencies: 250 to 6000 Hz · High Frequency tonal test: - Level (max): -10 to 100dB HL - 7 Frequencies: 8 to 16 kHz · Masking: narrowband or wideband · Automatically tonal audiometry
(Hughson-Westlake) · Transducers Plug & Play system · Automated calibration system · Speech audiometry test: SRT, WRS, UCL, MCL (sources: direct and/or recorded voice (CD, FLAC) | ADVANCED DIAGNOSTIC AUDIOMETER WITH HIGH
FREQUENCY AND RECHARGEABLE BATTERY: · Screening · Via air conduction: - Level (max): -10 to 120dB HL - 11 Frequencies: 125 to 8000 Hz · Via bone conduction: - Level (max): -10 to 80db HL - 9 Frequencies: 250 to 6000 Hz · High Frequency tonal test: - Level (max): -10 to 100dB HL - 7 Frequencies: 8 to 16 kHz · Masking: narrowband or wideband · Automatically tonal audiometry
(Hughson-Westlake) · Transducers Plug & Play system · Automated calibration system · Speech audiometry test: SRT, WRS, UCL, MCL
(sources: direct and/or recorded voice (CD, FLAC) · Li-Po 37Wh Battery |
HARDWARE Includes:
·
Calibrated DD45 headphones (standard)
·
Calibrated B71W Bone Vibrator
·
Patient response switch
·
Power supply
·
Ethernet cable (network)
·
Patient microphone)
·
Operator headset
SOFTWARE Included:
·
Data Base Software:
o Patients and tests database
o Patient management
o Appointment calendar management
·
Diagnostic Suite:
o Test report with colour audiogram:
§
Index calculation: ELI, SAL and
Modified Klockhoff
§
Diagnostics including Hearing Loss
degree:
ü
1979 AMA (American Medical
Association)
ü
BSA: British Society of Audiology
ü Fletcher Index