· NIBP, Pulse, MAP, SpO2, Temperature (optional)
· Clinically validated blood pressure measurement for adults as well as newborns weighing as little as 1kg
· Highly precise and motion-tolerant PEARL SpO2 measuring device also suitable for critical patients (e.g. newborns), clinically validated
· Shock resistant
· Easy and fast operation due to the simple menus and perfectly integrated storage options for sensor and cuffs
· Standard features include additional spiral tubing for a total tube length of approx. 2m including cuff as well as a finger sensor with a cable approx. 90cm in length, optional Sp02-extension available for a total length of 2.10m
· Efficient Li-Ion battery pack (approx. 500 measurements)
ri-vital® spot check monitor, engineered for the mobile, precise and fast recording of vital signs data at clinics, hospitals and outpatient treatments. Ergonomical design and highly developed technology resulting in reliable measurement results and time efficiency.
·
NIBP, Pulse, MAP, SpO2, Temperature
(optional)
·
Clinically validated blood pressure
measurement for adults as well as newborns
weighing as little as 1kg
·
Highly precise and motion-tolerant
PEARL SpO2 measuring device also suitable for critical patients (e.g.
newborns), clinically validated
·
Shock resistant
·
Easy and fast operation due to the simple menus and perfectly integrated storage
options for sensor and cuffs
·
Standard features include additional
spiral tubing for a total tube length of approx. 2m including cuff as
well as a finger sensor with a cable approx. 90cm in length, optional
Sp02-extension available for a total length of 2.10m
·
Efficient Li-Ion battery pack
(approx. 500 measurements)
·
Infrared ear thermometer with probe
sheath dispenser (optional)
·
Large, bright LCD display
·
Simultaneous measurement or different
vital parameters within seconds
·
Portable and light
·
Mobile stand (optional)
· 2 years warranty
Pulsoximeter: |
|
|
|
Measurement range SpO2: |
0..100% SpO2, |
|
|
Display range: |
0..99% SpO2 |
|
|
Accuracy: |
Adults +/-2% (70-100%) |
|
|
Pulse measurement range: |
30..250 min-1 |
|
|
Accuracy: |
+/- 1% |
|
|
|
|
|
|
Blood pressure: |
|
|
|
Measurement range: |
25.. 280mmHg (systole) |
|
|
Neonates |
20..155mmHg (systole) |
|
|
Overpressure protection: |
300mmHg |
|
|
Other: |
Independent protection system against excess pressures acc. to
EN1060-3 |
|
|
Measurement accuracy: |
acc. to EN1060-4:2005 |
|
|
Deviation from average value |
< 5mmHg |
|
|
|
|
|
|
Device: |
|
|
|
Mains |
115/230V, 50/60Hz |
|
|
Battery: |
ri-accu® L 7,4V Li-Ion battery |
|
|
Operation time: |
approx. 500 measurements NIBP and SpO2 |
|
|
Charging time: |
8 hours |
|
|
Mains adapter: |
AC/DC adapter plug, 100V-240V |
|
|
Display: |
Illuminated LCD |
|
|
Size: |
with thermometer |
|
|
Weight: |
1650 grams with thermometer 1500 grams |
|
|
Casing: |
PC+ABS |